Lexia 3 Download
The default software operating system of Lexia 3 V48 PP2000 V25 for Peugeot and Citroen is Windows XP with the latest service pack installed, but lexia 3 users have successfully installed PP2000 on Windows 7 operating system. DiagBox v7.77 = Lexia Softwae Version= 500.71 & Lexia Interface Firmware = 4.3.3 (.NET 3.5 is needed, run as Administrator or XP compatibility) The 4 points you need to consider for a successful DiagBox v7.xx on Windows 10 installation are. Full download BMW INPA EDIABAS NCS Expert WinKFP BMW Coding Tool - 15,546 views; PSA Diagbox 9.12 & 7.83 free download for Lexia 3 diagnostic tool - 12,190 views; Crack Ksuite 2.47 Kess V2 5.017 Free Update and Download- No Need Active - 8,949 views; OPCOM Firmware 1.70 1.65 download free: VAUX-COM 100% tested & working - 6,096 views. Lexia Core5 Android latest 4.2.0 APK Download and Install. Lexia Core5 Reading. These lexia 3 software download are professional-grade, and yet, simple enough to be used by amateurs as well. They can also help in fixing all kinds of crucial systems such as transmissions, engines, brakes, safety, emissions and so on. These lexia 3 software download are electrically powered and come with warranty periods.
PSA Lexia 3 Diagbox software is verified to work good on:
Windows XP
Windows 7 32bit or 64bit
Windows 8 32bit or 64bit
Windows 10
In details…
PSA Diagbox Windows XP
– I try to run my XP disc but it tells me that this PC model does not recognize this type of cd.
– had success with Window XP
trick to install another operating system eg XP or windows 7
1) at startup press the key to access UEFI ( bios) often it’s LED
2) look for Secure Boot line ex: at Asrock it’s the Security tab, while at the bottom line security boot
for asus tab boot via line Security Boot Parameters
3) once found change: Windows 8 UEFI in Other Legacy & UEFI
4) leave UEFI (bios) by validating the modifs
and voila you can install any OS even linux
moreover the new PCs have unformatted NTSF hard disks, so you have to reformat them in this format
**** Tip: How to install Lexia 3 Diagbox on Windows XP ****
Diagbox Windows 7
– anyway it takes 32bits whether for vista / seven or eight
– In any case with windows seven I have no particular problems it works pretty well. It seems to me that Windows 8 is not very different from the 7.
– with seven 32 bits you can do the van / can and all can
– with seven 64 only all can
– windows 7 or xp better
**** Tip: How to install Diagbox sw Windows 7 ****
you need to Disable UAC for Windows 7:
Open Control Panel
Go to User Accounts and Family Safety
Go to User Account
Go to Change User Account Control Settings
Chose when to be notified about changes to your computer –
Make it NEVER NOTIFY
Press OK ,
Load Diagbox , or read below first.
Lexia 3 Iso Download
To turn off warnings about UAC
Go to control Panel
Go to System and Security
Go to Action Centre
Press change Action Centre Settings
De-Select UAC
Press OK
Now Load Diagbox
Source: http://obd2-diag.blogspot.com/2017/11/clone-lexia-3-review.html
Diagbox software Windows 8
– Win7 / 8 in 32 bits does very well
– In Windows 8 32 bits, Diagbox 7.40 works well at home.
– with w8 32 the 2 protocols
– no problems with Windows 8 even upgrade to v7.11
– Even if it works I do not advise you to do the telecodage because pp2000 and lexia are done under kernel Xp mefie you it’s not because it works it’s operational to 100/100 (vecu) finally everyone does what he wants
– apparently strongly disadvised to run on Windows 8, but hey it may be able to do all the necessary test to see if it can really work or not otherwise than Windows xp
– 3 months that I use diagbox under windows 8 and pp2000 and lexia works very well just think to start the support in admin c is all
– Ditto for me with Diagbox 7.16 under win8 64.
I have not tested Lexia and PP2000
– diagbox 7.16 opens well under Windows 8 64 bit.it recognizes the wine of the car asks the dam but after pp2000 does not work.j have to try in admin mode similar pp2000 does not work
– Windows 8 not possible to put xp3 on a new machine
– no Lexia & PPS does not work under Windows 8 …
– Hi for my part I installed win8 32 everything works fine no problem I made diagnoses in pp200 and lexia for the old Peugeot and Citron no problem I also installed clip worm 131 also VCDS 11.11.4
– for my part everything works on windows 8- 32bits, I use XP sp3 compatibility mode to launch diagbox 7.19
more my interface is not flasche and the updates of this one not blocked
– I too diagbox 7.16 opens well under Windows 8 64 bits. It recognizes the wine of the car and works properly. pp2000 does not work
– I work with windows 8 32bits and I have no problem with remote or other.
– This is true on some new PC UEFI (bios) is set only Windows 8 by the motherboard manufacturer
PSA Diagbox Windows 10
– I have Diagbox 7.65 working fine on Windows 10 32 bit.
– I have windows 10 on my laptop but I have 3 virtual machines setup for Diagbox (7.65)/Diagbox (7.62 – Oflfine) / Planet
Its fiddly to set up, but once you have done it, you can move all 3 virtual machines onto another computer in seconds.
Plus you don’t have any compatibly issues!
– I have compatibility on Windows 10, although I’m not running up to 7.65, maybe I’ll give that update a go.
– Just ended up looking at this thread because I have a notification on my Diagbox which I recently installed on my laptop, that says do not install windows 10!
This seems to contradict the fact that its already running on windows 10 and its the 64bit vesrsion aswell
– Diagbox at the moment cannot run in Win 10
– No Diagbox dont work in Windows 10
ne pas installer Windows 10(in french) = dont install windows 10 (in english)
– Diagbox runs on windows 10 64bit with gpt
**** Tip: How to install Lexia 3 Diagbox on Windows 10****
provided that:
1- Hard Disk Controller is set to IDE/Legacy (not AHCI or SCSI),
2- Partition type is MBR (not GPT),
3- .NET 3.5 is installed,
4- Run DiagBox as Administrator.
In details… 4 points what you need to consider :
Lexia 3 V7.83 Download
1- You are probably installing (Windows 10) as GPT, you may need to change to MBR, so that you can use IDE (Legacy) hard disk controller, else you will get the dreaded error 0. Changing from (AHCI) to IDE may impose speed penalty; depending on your hardware.
Controller/Mode types:
• IDE (Integrated Drive Electronics) is the older HDD 40/44/80 pin parallel ATA interface drive. Setting this mode in the BIOS allows the newer SATA drive to emulate an old Parallel ATA drive (Suitable for Windows XP which did not support SATA at that time).
• AHCI (Advanced Host Controller Interface) supports newer faster and larger drives and has the NCQ (Native Command Queuing) extension, which allows hard disk drives to internally optimize read and write commands execution.
Partition types:
• MBR (Master Boot Record) cannot address more than 2.2TB drives and is limited to 4 primary partitions max.
• GPT (GUID Partition Table) supports partitions of more than 2TB.
Installing DiagBox on Windows where the BIOS is set to AHCI (for better SATA drive utilization) usually fails giving error 0. But it installs and runs on hard disks configured as IDE.
If your BIOS is set to AHCI and windows is installed on a GPT partition, Windows 10 will NOT boot (but Linux will) when you change the BIOS setting to IDE. So in order to boot Windows 10 with the BIOS set to IDE, the partition type needs to be changed to MBR first, then you set the BIOS to IDE or Legacy before installing DiagBox.
However, I have changed the type of Disk on my Windows 10 from IDE to SATA, and my DiagBox current installation still works, see attached photo !!!…
The best and easiest way is to add the other controller type and boot into Windows so that the drivers are loaded and Windows can boot either way before changing from one type to the other.
2- You need to install .NET 3.5 if you want to install or DiagBox v7.66 above. I also had Firefox installed.
3- You (may) need to plug-in the Lexia 3 interface and install the drivers “ACTIAPnPInstaller.exe” before installing DiagBox v7.01 to ensure the multyinstance driver is installed.
4- You need to run DiagBox as administrator or in XP compatibility mode for v7.74 and above. Otherwise you will get a message to reactivate.
Registry editor for mac. DiagBox v7.76 is the latest and “may be” the last from Actia while moving to v8.xx. I don’t think any further development is expected for v7.xx, they are unlikely to support a “sunset” product, the release of the new “A.1281 Z” interface could be an indication!!
Source:http://blog.obd2diy.fr/2017/11/22/how-to-install-psa-diagbox-7-76-windows-10/
Qui ont consulté cet article ont également consulté:
Lexia3 PP2000 Diagbox V9.12 V8.26 V7.83 V7.76 V7.57 all previous versions are available to free download with given password, but please try at your own risk. And hope it is helpful.
Tips: before downloading, please exit/uninstall firewall or antivirus i.e. Avast, Avira, Bitdefender… and run update on administrator privilege.
Diagbox 9.12 free download
Diagbox v09.12 original and unchanged.
maybe of use to someone for personal research and development.
it is offered as is and with no support from myself.
Lexia3 PP2000 Diagbox V8.26 updated from V8.20:
No password.
Works on the interface: Lexia-3 V48 PP2000 V25 with Original 921815C Chip can do Peugeot 307
Lexia DiagBox v7.83 (8.19) updated from v7.82:
Password: Very Simple!
Test result: Free source, not sure if it is 100% yes with Lexia3 V48 PP2000 V25, if you tried with no joy, try the CD version diagbox.
Diagbox 7.83 installation: https://www.youtube.com/watch?v=YanWwNn_fiU
System Requirements: Windows XP, 512 MB RAM
Language: Multi-language
Diagbox 7.83 vehicle coverage:
Peugeot: 107, 206, 207, 307, 308, RCZ, 407, 508, 607, 1007, 3008, 4007, 5008, BIPPER, PARTNER, EXPERT, BOXER, 106, 205, 306, 309, 405, 406, 605, 806, 807 etc.
Citroen: C1, C2, C3 DS3, C4, DS4, C5, C6, C8, C-CROSSER, NERO, BERLINGO, JUMPY, AX, SAXO, BX, ZX, XSARA, XANTIA, XM, EVASION, C15, C-ZERO etc.
DiagBox V7.82 (8.18) updated from V7.76:
Password: Maitresox01
DiagBox software V7.74 updated from V7.66:
Password: Maitresox pour TLEMCEN TE-100%
Lexia3 DiagBox V7.66 updated from V7.62:
Password: @-Maitresox-MHHAUTO
DiagBox V7.62 updated from V7.58:
PSA DiagBox V7.58 updated from V7.57:
PSA DiagBox V7.57 updated from V7.01: